Rock Coal Permeability Coefficient Tester
Working principle
Based on Darcy's Law, the permeability coefficient is calculated by measuring the steady-state flow rate of a fluid under a constant pressure gradient.

Application area

Geological Engineering: Evaluating the rock permeability of oil and gas reservoirs, geothermal extraction, and nuclear waste disposal facilities.
Civil Engineering: Rock Mass Seepage Characteristics in Tunnel and Slope Stability Analysis.
Research and Teaching: Experimental Research in Rock Mechanics and Hydrogeology.
Standard specifications:
Follow international standards such as ASTM D4525 and ISO 17313.
Parameter
|
|
Variety |
Name |
Parameter |
|
1 |
|
Maximum test force |
2000KN.(300KN;1000KN) |
|
|
|
Accuracy class |
Level 1 |
|
2 |
Load parameters |
Test force measurement range |
0.4%~....FS(Full range) |
|
|
|
Test force indication error |
示值的±0.5% |
|
|
|
Test force resolution |
± 1/300000 of the maximum test force, no gear division throughout the entire process, and constant resolution throughout the entire process |
|
3 |
Control parameters |
Range of force control rate adjustment |
0.005~5%FS/s |
|
|
|
Force control rate control accuracy |
When the speed is less than 0.05% FS/s, it is within ± 2% of the set value, and when the speed is greater than or equal to 0.05% FS/s, it is within ± 0.5% of the set value; |
|
|
|
Test bench speed adjustment range |
0.1~250mm/min |
|
|
|
Test bench speed control accuracy |
Within ± 0.2% of the set value |
|
|
|
control range |
0.5%~....FS |
|
|
|
control accuracy |
When the set value is ≥ 10% FS, it is within ± 0.5% of the set value. When the set value is < 10% FS, it is within ± 1% of the set value |
|
4 |
Host Parameters |
External dimensions |
910×400×1200mm |
|
|
|
Maximum stroke of oil cylinder piston |
150mm |
|
|
|
Maximum distance between upper and lower pressure plates |
450mm |
|
|
|
Power |
380V/50Hz,±10% |
|
|
|
Weight |
900Kg |
|
5 |
Surrounding pressure |
0~20MPa±0.02kPa Adjustable settings, LCD display |
|
|
6 |
Permeation reverse pressure water pressure |
0~60MPa±0.02kPa Adjustable settings, LCD display |
|
|
7 |
Test specimen |
¢50mm×100mm ;¢25mm×100mm;Specialized rubber film; Other sizes can also be optionally selected |
|
|
8 |
Permeability coefficient acquisition instrument |
Water output accuracy: 0.2ml; Automatic data collection; real time display。 |
|
|
9 |
triaxial cell |
Thick walled seamless steel material, capable of withstanding high pressure |
|
description2