Leave Your Message

Petroleum Products Asphalt Kinematic Viscometer Kinematic Viscosity Tester Capillary Viscometer

This Kinematic Viscosity Testing Machine is designed and made as per the industrial standard of People's Republic of China SY/T5651 Technical Condition of Petroleum Products Kinematic Viscosity Tester, GB/T 265 Petroleum products-Determination of kinematic viscosity and calculation of dynamic viscosity and ASTM D445 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids. It is suitable to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer at a constant temperature.

    PRoduct Features

    1. Single chip microcomputer and colored LCD technology. High intelligence and automation.
    2. Intelligent signal sampling, data measuring, parameters operating, and result output. All the operations are finished automatically.English man-machine conversation interface. Easy to operate.
    3. The instrument is equipped with timing function. It can choose valid flowing time period and calculate arithmetic average automatically. It can also preset the viscosity coefficient , calculate the viscosity after the test and print the test results automatically.
    4. It can do one test alone or doing two tests at one time by setting the parameters.High efficiency.
    5. It has the parameters saving function. The instrument will automatically save the parameters of capillary tube diameter, coefficient and so on after these parameters being setted. When doing test with the same capillary, no need to set these parameters again.
    6. It adopts desktop and all-in-one machine design. Convenient to use.

    Operation method

    Preparation: Check whether the instrument components are normal, calibrate the instrument, select a capillary viscosity tube with a suitable coefficient according to the viscosity of the oil, and prepare the sample to be tested with uniform mixing and suitable temperature.

    Set parameters: Set the viscometer constant, control temperature value, fine-tune temperature value, number of tests and other parameters through the touch screen or buttons.

    Measurement process: Inject the sample into the viscometer tube, start the measurement program, and the instrument automatically controls the constant temperature of the bathtub to stabilize the sample at the set temperature for a period of time.

    Record data: The instrument automatically records the time when the liquid flows through the viscometer, and calculates the kinematic viscosity based on the time and instrument calibration data.
    Cleaning and maintenance: After the measurement is completed, the instrument automatically cleans and dries the capillary viscometer for next use, and regularly cleans the outside of the instrument and inspects the components.

    Specification

    1. Power supply:AC(220±10%)V, 50Hz
    2. Bath heating power:1700W
    3. Temperature range:Room temperature~100.0℃
    4. Temperature control accuracy:±0.01℃
    5. Bath volume:20L
    6. Timing range: 0.0s~9999.9s
    7. Timing accuracy: ±0.05% within 60min
    8. Amount of capillary viscometer tubes: 4 capillary viscometers
    9. Stirring motor: Power 6W, rotating rate 1200RPM
    10.Working condition: ambient temperature-10℃~35℃, RH: ≤85%
    11.Temperature sensor: RTD, Pt100
    12.Maximum power consumption: 1800W
    13.Capillary viscometers tubes(Pinkevitch viscometer): 7 pieces in total.The inner diameter for each: 0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm, 2.5mm
    14.Dimension: 530mm×400mm×670mm

    Parameter

    Power supply

    AC(220±10%)V, 50Hz

    Heating power

    1700W

    Temperature range

    Ambient to 100.0℃

    Temperature control accuracy

    ±0.01℃

    Bath capacity

    20L

    Timing range

    0.0s~9999.9s

    Timing accuracy

    ±0.05% within 60min

    Amount of capillary viscometer tubes

    4 capillary viscometers

    Stirring motor

    6 W, 1200 RPM

    Working condition

    (Ambient temperature-10)℃~35℃, RH: ≤85%

    Temperature sensor

    RTD, Pt100

    Maximum power consumption

    1800W

    Capillary viscometers tubes(Pinkevitch viscometer)

    7 pieces in total.The inner diameter for each: 0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm, 2.5mm

    Dimension

    530mm×400mm×670mm

    description2